Solar Power (PV) 6.66 kW System: Key Attributes


High quality panels, internationally recognised for high output performance delivering you more power for each watt installed. Individually quality tested and proven product that will stand up to the harshest Australian conditions.
Show less

Solahart Solar Power Systems can be upgraded in the future to include a battery storage system to increase the amount of power you can use from the sun. To learn more about battery storage systems, contact your local Solahart dealer.
Show less

We provide a trusted Solahart warranty on all our products, which means years of trouble-free, worry-free energy.
Show less

Most suitable for areas that receive low to medium levels of solar radiation,
Show lessKey Features
Our new high-performance Solahart panel, with stylish black appearance, is the ideal solution for Australian homes thanks to its innovative and premium cell technology. Read more here.
The SolarEdge PV inverter is designed to work with the SolarEdge Power Optimizers that manage each solar panel separately. Consequently, the inverter is only responsible for DC to AC conversion which makes it a less complicated and more reliable solar inverter. A fixed string voltage ensures operation at the highest efficiency at all times, independent of string length and temperature.
The SolarEdge inverter is fully compatible with the Tesla Powerwall Battery and LG Chem Battery.
The SolarEdge Power Optimizer connects to a single panel to monitor and control its performance, individually. This level of control mitigates all types of panel mismatch losses, from manufacturing tolerances to partial shading and improves the performance of the PV system. It allows for more flexible system designs and maximum space utilisation.
- Compatible with the LG Chem and Tesla Powerwall Batteries
- Designed specifically to work with Power Optimizers
- Independent, panel-level management and monitoring
- More power generated from system
^ Energy savings of up to 9200 kWh/year is based on the average amount energy produced per year by the PVG6660C50 solar power system in Zone 3. Savings and incentives will vary depending upon your location, type of Solahart system installed, orientation and inclination of the solar panels.
† Solahart Warranty Details:
- Solar Panels: 25 years,
- Inverter and Optimisers: 12 years,
- Racking and Balance of System components: 5 years,
- Labour: 5 years,
- For full warranty details refer to the Solahart Owner’s Guide.
PVG6660C50 Specifications
Solahart Solar Panel Specifications
Panel Electrical Characteristics | |
---|---|
Maximum Power (Pmax) Power Class |
370W 0/+5W |
Open Circuit Voltage (Voc) | 44.97V |
Short Circuit Current (Isc) | 10.44A |
Maximum Power Voltage (Vmp) | 37.28V |
Maximum Power Current (Imp) | 9.92A |
Module Efficiency (%) | ≥19.5% |
Temperature Coefficients | |
PMPP VOC ISC |
-0.36%/ K -0.27%/ K +0.04%/ K |
Maximum System Voltage ( IEC ) | 1000V |
Panel Specifications | |
Dimensions | 1840 mm x 1030 mm x 32 mm |
Weight | 19.5 kg |
Cell Type and configuration | 6 x 22 monocrystalline solar half-cells |
Glass | 3.2mm thermally pre-stressed glass with anti-reflection technology |
Back sheet | Composite film |
Frame | Black Anodised Aluminium |
Temperature range | -40°C to + 85°C |
Junction Box | Protection Class IP 67, with bypass diodes |
Connectors | Multi-contact MC4, IP68 |
Part Number | Solahart370S2 |
Solahart Warranty | 25 years (5 years labour) on panels* |
Solar Inverter Specifications
Inverter Technical data: SE5000H | |
---|---|
Output (AC) | |
Rated AC Power Output | 4985VA |
Maximum AC Power Output | 4985VA |
AC Output Voltage (Nominal) | 220/230V |
AC Output Voltage Range | 184-264.5V |
AC Frequency (Nominal) | 50 ± 5Hz |
Maximum Continuous Output Current | 21.7A |
Residual Current Detector / Residual Current Step Detector | 300/30mA |
Utility Monitoring, Islanding Protection, Country Configurable Thresholds |
Yes |
Input (DC) | |
Maximum DC Power (Module STC) | 7750W |
Transformer-less, Ungrounded | Yes |
Maximum Input Voltage | 480V |
Nominal DC Input Voltage | 380V |
Maximum Input Current | 13.5A |
Reverse-Polarity Protection | Yes |
Ground-Fault Isolation Detection | 600kÙ Sensitivity |
Maximum Inverter Efficiency | 99.2% |
European Weighted Efficiency | 98.8% |
Night time Power Consumption | <2.5W |
Additional features | |
Supported Communication Interfaces | RS485, Ethernet, Wi-Fi (optional) |
Smart Energy Management | Export Limitation, StorEdge applications |
Standard compliance | |
Safety | IEC-62109, AS-3100 |
Grid Connection Standards | AS/NZS-4777:2015 |
Emissions | IEC61000-6-2, IEC61000-6-3,IEC61000-3-11, IEC61000-3-12, FCC part15 class B |
RoHS | Yes |
Installation specifications | |
AC Output | 19 - 25 mm Conduit |
DC Input | 19 - 25 mm Conduit |
Dimensions (W/H/D)mm | 370 / 450 / 174 mm |
Weight | 11.4 kg |
Cooling | Natural Convection |
Noise | <25 dBA |
Operating Temperature Range | -20˚C to 60˚C |
Protection Rating | IP65 - Outdoor and Indoor |
Product Details | |
SolarEdge Part Number | SE5000H |
Solahart Warranty | 12 years1 |
Power Optimizer Technical data | |
---|---|
Input (DC) | |
Rated Input DC Power2 | 370W |
Absolute Maximum Input Voltage (Voc at lowest temperature) | 60V |
MPPT Operating Range | 8-60V |
Maximum Continuous Input Current (Isc) | 11A |
Maximum Efficiency | 99.50% |
Weighted Efficiency | 98.80% |
Overvoltage Category | II |
Output during operation (Power Optimizer connected to operating SolarEdge inverter) | |
Maximum DC Output Current | 15A |
Maximum DC Output Voltage | 60V |
Output during standby (Power Optimizer disconnected from SolarEdge inverter or SolarEdge inverter off) | |
Safety Output Voltage per Power Optimizer (DC) | 1V |
Standard compliance | |
EMC | FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 |
Safety | IEC62109-1(class II safety),UL1741 |
RoHS | Yes |
Fire Safety | VDE-AR-E 2100-712:2013-05 |
Installation specifications | |
Maximum Allowed System Voltage (DC) | 1000V |
Dimensions (W/H/D)mm | 129/153/27.5 |
Weight (including cables) | 655gr |
Input Connector | MC4 |
Output Connector | MC4 |
Output Wire Length | 1.20m |
Operating Temperature Range | -40˚C to 85˚C |
Protection Rating | IP68 |
Relative Humidity | 0-100% |
PV system design using a SolarEdge inverter | |
Minimum String Length (Power Optimizers) | 8 |
Maximum String Length (Power Optimizers) | 25 |
Maximum Power per String | 5700W (HD Wave) |
Parallel Strings of Different Lengths or Orientations | Yes |
Product Details | |
SolarEdge Part Number | P370 |
Solahart Warranty | 12 years1 |
1 For full details see Solahart Owner’s Guide and Installation Instructions. Conditions apply.
2 Rated STC power of the module. Module of up to +5% power tolerance allowed.
How Solar Power (PV) Systems Work
Solar power panels generate electricity from sunlight. The roof mounted solar panels are made up of many photovoltaic (PV) cells. These cells collect the sun’s light and convert the energy into DC electricity. This is fed through an inverter and converted to 240V AC electricity to power your home.
The amount of electricity you can produce depends on the number and efficiency of the panels, the size of the inverter and the amount of sunlight in your location. Your home remains connected to the electricity grid so when you generate more electricity than you need you can feed it into the grid or purchase more from the grid when you are not producing enough to meet your requirements.
Solar Power System Design
The Solahart Solar Power system is comprised of two main components; a string or array of photovoltaic panels and an inverter. The photovoltaic (PV) panels transform solar radiation into electrical energy in the form of direct current (DC). In order to utilise this energy and feed it back into the grid, the direct current is transformed into alternating current (AC) by the inverter. This conversion is also known as DC to AC inversion.
The alternating current generated by the inverter is fed into the main switchboard, which in turn is connected to the electricity grid. If the energy generated exceeds that required by property demands, your electrical network operator may allow the difference to be directly injected into the grid and become available to other users. Energy injected into the grid can be measured by electricity network operators as either gross (everything generated) or nett (excess generated). Injected energy may or may not be purchased by the local electrical network operator according to national and local standards, and regulations.
PV Panel Orientation & Inclination
To maximize system output, install panels at optimum orientation and inclination (tilt) angles. The specifics of this will depend on the installation location and must be calculated by a qualified system designer. The ideal angle for mounting a panel should result in the sun’s rays falling perpendicular (i.e. at a 90° angle) to the panel surface.
Panels should be installed in a shade free position. Even minor or partial shading of the panels/array will reduce system output. A panel is considered shade free when it is both:
- Free from shade or shadows all year round.
- Exposed to several hours of direct sunlight, even during the shortest days

Brochures
Solahart Silhouette Solar Panel (370W): Download
Solahart Solar Power (PV) HD Wave Inverter SE5000H: Download
Solahart Solar Power (PV) Inverter SE5000 with Backup: Download
Solahart Solar Power (PV) SolarEdge DC Optimisers: Download
Installation Manuals
Solahart370S2 Panel's Installation Instructions: Download
Solar Incentive Forms
Small-scale Technology Certificate Assignment Form: Download
Warranty
Solahart Warranty: Download