Skip to main content

Book your assessment

Find a local dealer

With Solahart, you get the best of both worlds: unbeatable service from your local authorised dealer and the unrivalled support of Australia’s solar experts for over 70 years.

Toggle postcode results dropdown
 

Solahart Atmos EcoSplit 5kW

Split Heat Pump Water Heater

The Solahart Atmos EcoSplit 5kW Heat Pump is ideally suited for homes with narrow spaces or as a replacement for a similar-sized electric water heater. 

6**
Family size
320L
Capacity
10*yr
Warranty
78%#
Water Heating Energy Savings

Solahart Atmos EcoSplit 5kW: Key Attributes

Why Atmos Split is a smart choice

The Solahart Atmos® EcoSplit 5kW with a 320L VE tank is a powerful Ultra Low GWP R290 split heat pump.

It is a smart heat pump, designed for people looking for an energy-efficient alternative to an electric water heater, but whose homes may not be suitable for installing a solar hot water system and whose outdoor space is limited.

This outstanding two-part unit comprises a refrigeration/heat exchanger module that’s similar to a split air-conditioner, and a water tank which can be installed near, or at a distance, depending on the requirement.

The module is designed for Australia, with tanks manufactured in Australia.

High Heating Capacity

A high 4.6kW heating capacity at 19°C for your fast hot water needs

High COP of 4.5 @ 19°C

High efficiency with a Coefficient of Performance (COP) of 4.5 @ 19°C ambient temperature†, delivering outstanding performance, and helping you reduce energy consumption and costs.

Suitable for cold climates

Operating range from -7°C ~ 43°C

High Energy Savings

Can save up to 78% on your water heating energy consumption# compared to an electric water heater in Zone 3.
  • Specifications
    Tank Model
    CER Submitted (L) 315
    Nominal/Storage Capacity (L) 320
    Tank height (mm) 1640
    Tank width (mm) 640
    Tank depth (mm) 640
    Tank weight – empty (kg) 89
    Tank weight – cartoned (kg) 96
    Tank weight – full (kg) 414
    TPR Valve Setting (kPa) 1000
    Expansion Control Valve (ECV) Setting (kPa) 850
    Maximum Water Supply Pressure with ECV (kPa) 680
    Maximum Water Supply Pressure without ECV (kPa) 800
    Water Connections Rp 3/4
  • How it works

    Why Choose a Split Heat Pump Water Heater?

    Discover the smarter way to heat your water with a system designed for efficiency, flexibility, and peace of mind.

    Save Energy, Save Money

    Cut your energy use by up to 78% compared to standard electric water heaters. That means lower bills and a smaller carbon footprint—good for your wallet and the planet.

    Perfect for Tight Spaces

    No backyard? No problem. The compact design allows the tank to be installed indoors, like in your garage, making it ideal for homes with limited outdoor space.

    Quiet by Design

    Enjoy a peaceful home environment with low-noise operation—engineered to run quietly day and night.

    Simple Installation

    With a water-connected split system, any licensed plumber can install it—no need for specialist refrigeration technicians.

    Lower Upfront Costs 

    Skip the extra expense of hiring refrigeration experts. This system is designed to be installed easily and affordably.

    Easy Maintenance 

    Accessing the unit and tank is straightforward, making routine maintenance quick and stress-free.

    Leak-Resistant Confidence

    The refrigerant system is factory-sealed to reduce the risk of leaks, giving you long-term reliability and peace of mind.

    Backed by Solahart’s National Dealer Network

    Solahart's trained dealer network Australia-wide service team is here to help with warranty repairs, expert advice, and ongoing support—so your system keeps performing year after year

  • Downloads
  • *Warranty Details
    • 10 years cylinder supply
    • 3 years cylinder labour
    • 3 years sealed system supply and labour
    • 1 year parts supply and labour

    *The warranty periods above apply to a single-family domestic dwelling only. See the Solahart warranty set out in the Owner’s Guide and Installation Instructions or view at www.solahart.com.au/warranty

    Warranty limits regarding water chemistry. Harsh water regions – the Solahart warranty may not apply if the water heater is connected to a water supply which has a Total Dissolved Solids content >2500mg/L; is scaling with a Saturation Index >+0.8, or; is corrosive with a Saturation Index <-1.0.

    **No. of people recommended based on 7 min showers @ 42°C. Appliances using hot water should be counted as one (1) person.

    †The COP of 4.5 is the average value in the AS/NZS5125 performance test at 19°C ambient temperature over the entire heat-up process. Note that the actual COP of the product at any given time will be impacted by several factors, including the ambient and cold-water inlet temperatures at the place of installation and time of day/season of operation.

    #Energy savings of up to 78% and 80% are based on operation at Condition #2 & Condition #4 of AS/NZS 5125. Any savings will vary depending upon your location, type of water heater being replaced, hot water consumption and fuel tariff. Before installation – seek advice as to suitability to household usage and tariffs. The impact on an electricity account will depend on the tariff arrangement of the water heater being replaced and where you live. The water heater is recommended for connection to an uninterrupted 24 hour continuous tariff power supply. Depending upon the size of the household and its hot water requirements and if the Electricity Retailer permits, an extended off-peak (overnight and day) or Extended time controlled power supply connection of a minimum 16 hours per day may also be suitable. Before purchase consult your energy provider for more information on cost comparisons.

    ‡Noise Level – A noise level of 47 dB(A) was measured at 1m from the water heater during a Noise Test conducted to Standard GB/T 23137-2008 in a semi-anechoic chamber within a laboratory. The noise level when installed may be higher due to sound reflections from adjacent walls and structures.