Most suitable for areas that receive medium to high levels of solar radiation, and is suitable for frost prone or harsh water chemistry areas.
Show less

Corrosion protection for the water heater’s solar tank is achieved by using a proven, high quality vitreous enamel lining on the tank. Additional protection is gained by the use of a sacrificial anode.
Show less

The electric boosted models are equipped with an in-tank element.
Show less

Switch to a Solahart solar water heater and save up to 2.7 tonnes of carbon emissions per year, which is equivalent to taking a small car off the road.
Show lessKey Features
The tank features Solahart Super-Shield™ enamel for enhanced protection, as well as a protective sacrificial anode to improve the life of the tank.
The Sunheat Series also utilises Solahart flat plate collector technology. This results in extra-strong glass that is resistant to breaking. Flat plate collectors provide a stronger, safer application when installed on your roof and give greater durability and sustainability than evacuated tubes.
151BPT Solar Specifications
Tank Model | 150L Tank | 151L System |
---|---|---|
Storage Capacity | 150 Litres | 150 litres |
Boost Capacity (Electric) | 75 litres | 75 litres |
Weight Empty | 44 kg | 76 kg |
Weight Full | 194 kg | 128 kg |
A-Width | 1.66 m | 1.66 m |
B-Length | 0.45 m | 2.487 m |
BPT Collectors | |
---|---|
Aperture (heating) Area | 1.87 m2 |
Dimensions | |
Length | 1940 mm |
Width | 1024 mm |
Height | 80 mm |
Capacity | 1.5 litres |
Weight* | |
Empty | 32 kg |
Full | 34 kg |
Working Pressure | 1000 kPa 145 psi |
Absorber Surface | Black polyester powder coat |
Absorber Material | aluminium |
Riser Material | copper tube |
Tray Material | 0.7 mm aluminium |
Insulation Material - Base | 38 mm polyester blanket |
Glass | 3.2 mm tempered low iron glass |
*Weight includes fittings
Electric Boost Specifications | ||||
---|---|---|---|---|
Heating Unit Type | Cooper sheath immersion element | |||
Supply Voltage | 240 V -250 V | |||
Recovery Rate (litres/hour) @ 240V and Temperature Rise of: | ||||
Rating kW |
Current Amps |
30°C litres/hour |
40°C litres/hour |
50°C litres/hour |
1.8 | 8 | 51 | 39 | 31 |
Water Supply | |
---|---|
TPR Valve Setting | 1000 kPa 145 psi |
ECV* Setting | 850 kPa 125 psi |
Max. Supply Pressure | |
With ECV | 680 kPa |
Without ECV | 800 kPa |
Water Connections | |
Cold | DN15 compression fitting |
Hot | R 1/2 |
*Expansion Control Valve.